Dimensions and air flow | |
Dimensions of nozzle (width x height) | 1.575 m x 1.05 m |
Exit area of nozzle | 1.654 m2 |
Contraction ratio | 4.95 |
Length of open-nozzle test section | 2.585 m |
Diameter of axial fan | 2.0 m |
Operating output | 335 kW (1050 1/m) |
Max. flow velocity | 288 km/h |
|
|
Displacement heigth of boundary layer in the center of the ground plane (x=0) | |
- without boundary layer influence | 4.5 mm |
- with boundary layer pre-suction | 2.4 mm |
- with road simulation | Block profile |
|
|
Ph.: +49 711 685-63110 oder 63130
Mobile: +49 172 9329172