Overview of Conditioning Systems and Additional Assemblies

The existing conditioning systems – currently approx. 50 – were largely created in-house. Besides the conditioning systems, the inventory of aggregates also includes unregulated cooling assemblies and various supply assemblies.

Conditioning system for

Controlled variables

Coolant

T-control

Charge air (coolant of CAC)

T-control to charge air cooling

Lubricating oil

T-control, partially p-control

Fuel

T-control

Intake air

T-control, p-control

External charging systems

T-control, p-control

Exhaust back pressure

p-control

Unregulated cooling assemblies for

Fuel

Lubricating oil

Indexing sensor system

Additional supply assemblies for

Lubricating oil

Gasoline direct injection

Special assemblies

Manufacturer

Coolant assembly up to -25 °C

L&R Kältetechnik

Intake air assembly up to -20 °C

Weiss Umwelttechnik