The existing conditioning systems – currently approx. 50 – were largely created in-house. Besides the conditioning systems, the inventory of aggregates also includes unregulated cooling assemblies and various supply assemblies.
Conditioning system for | Controlled variables |
Coolant | T-control |
Charge air (coolant of CAC) | T-control to charge air cooling |
Lubricating oil | T-control, partially p-control |
Fuel | T-control |
Intake air | T-control, p-control |
External charging systems | T-control, p-control |
Exhaust back pressure | p-control |
Unregulated cooling assemblies for |
Fuel |
Lubricating oil |
Indexing sensor system |
Additional supply assemblies for |
Lubricating oil |
Gasoline direct injection |
Special assemblies | Manufacturer |
Coolant assembly up to -25 °C | L&R Kältetechnik |
Intake air assembly up to -20 °C | Weiss Umwelttechnik |